9,414 research outputs found

    Are the arms and head required to accurately estimate centre of mass motion during running?

    Get PDF
    Accurate measurement of centre of mass (CoM) motion can provide valuable insight into the biomechanics of human running. However, full-body kinematic measurement protocols can be time consuming and difficult to implement. Therefore, this study was performed to understand whether CoM motion during running could be estimated from a model incorporating only lower extremity, pelvic and trunk segments. Full-body kinematic data was collected whilst (n = 12) participants ran on a treadmill at two speeds (3.1 and 3.9 ms−1). CoM trajectories from a full-body model (16-segments) were compared to those estimated from a reduced model (excluding the head and arms). The data showed that, provided an offset was included, it was possible to accurately estimate CoM trajectory in both the anterior-posterior and vertical direction, with root mean square errors of 5 mm in both directions and close matches in waveform similarity (r = 0.975-1.000). However, in the ML direction, there was a considerable difference in the CoM trajectories of the two models (r = 0.774–0.767). This finding suggests that a full-body model is required if CoM motions are to be measured in the ML direction. The mismatch between the reduced and full-body model highlights the important contribution of the arms to CoM motion in the ML direction. We suggest that this control strategy, of using the arms rather than the heavier trunk segments to generate CoM motion, may lead to less variability in CoM motion in the ML direction and subsequently less variability in step width during human running

    Biological effects of soft denture reline materials on L929 cells in vitro.

    Get PDF
    Soft denture reline materials have been developed to help patients when their oral mucosa is damaged or affected due to ill-fitting dentures or post-implant surgery. Although reports have indicated that these materials leach monomers and other components that do affect their biocompatibility, there is little information on what cell molecules may be implicated in these material/tissue interactions. The biocompatibility of six soft liners (Ufi Gel P, Sofreliner S, Durabase Soft, Trusoft, Softone and Coe Comfort) was evaluated using a mouse fibroblast cell line, L929. Within 2 h of material disc preparation, each of the materials was exposed by direct contact to L929 cells for periods of 24 and 48 h. The effect of this interaction was assessed by alamarBlue assay (for cell survival). The expression of integrin α5β1 and transforming growth factor β1 was also assessed using plate assays such as enzyme-linked immunosorbent assay. Trusoft, Softone and Coe Comfort showed significantly reduced cell survival compared with the other soft lining materials at each incubation period. Furthermore, there were significant differences with these same materials in the expression of both integrin α5β1 and transforming growth factor β1. Soft liner materials may affect cell viability and cellular proteins that have important roles in wound healing and the preservation of cell viability and function in the presence of environmental challenges and stresses

    Occupational asthma: a review.

    Get PDF
    Occupational asthma is the most common form of occupational lung disease in the developed world at the present time. In this review, the epidemiology, pathogenesis/mechanisms, clinical presentations, management, and prevention of occupational asthma are discussed. The population attributable risk of asthma due to occupational exposures is considerable. Current understanding of the mechanisms by which many agents cause occupational asthma is limited, especially for low-molecular-weight sensitizers and irritants. The diagnosis of occupational asthma is generally established on the basis of a suggestive history of a temporal association between exposure and the onset of symptoms and objective evidence that these symptoms are related to airflow limitation. Early diagnosis, elimination of exposure to the responsible agent, and early use of inhaled steroids may play important roles in the prevention of long-term persistence of asthma. Persistent occupational asthma is often associated with substantial disability and consequent impacts on income and quality of life. Prevention of new cases is the best approach to reducing the burden of asthma attributable to occupational exposures. Future research needs are identified

    The MROI fringe tracker: Laboratory tracking with ICONN

    Get PDF
    The loop is closed on ICONN, the Magdalena Ridge Observatory Interferometer fringe tracker. Results from laboratory experiments demonstrating ICONN's ability to track realistic, atmospheric-like path difference perturbations in real-time are shown. Characterizing and understanding the behavior and limits of ICONN in a controlled environment are key for reaching the goals of the MROI. The limiting factors in the experiments were found to be the light delivery system and temporary path length correction mechanism; not the on-sky components of ICONN. ICONN was capable of tracking fringes with a coherence loss below 5%; this will only improve in its final deployment.The Magdalena Ridge Observatory Interferometer is funded by the US Department of Transportation, the State of New Mexico, and New Mexico Tech with previous funding from the Navy Research Laboratory (NRL, agreement no. N00173-01-2-C902).This is the final version of the article, also available from SPIE at http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1891933. Copyright 2014 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. http://dx.doi.org/10.1117/12.205560

    Violent video games and morality: a meta-ethical approach

    Get PDF
    This paper considers what it is about violent video games that leads one reasonably minded person to declare "That is immoral" while another denies it. Three interpretations of video game content a re discussed: reductionist, narrow, and broad. It is argued that a broad interpretation is required for a moral objection to be justified. It is further argued that understanding the meaning of moral utterances – like "x is immoral" – is important to an understanding of why there is a lack of moral consensus when it comes to the content of violent video games. Constructive ecumenical expressivism is presented as a means of explaining what it is that we are doing when we make moral pronouncements and why, when it comes to video game content, differing moral attitudes abound. Constructive ecumenical expressivism is also presented as a means of illuminating what would be required for moral consensus to be achieved

    Using Rasch analysis to form plausible health states amenable to valuation: the development of CORE-6D from CORE-OM in order to elicit preferences for common mental health problems

    Get PDF
    Purpose: To describe a new approach for deriving a preference-based index from a condition specific measure that uses Rasch analysis to develop health states. Methods: CORE-OM is a 34-item instrument monitoring clinical outcomes of people with common mental health problems. CORE-OM is characterised by high correlation across its domains. Rasch analysis was used to reduce the number of items and response levels in order to produce a set of unidimensionally-behaving items, and to generate a credible set of health states corresponding to different levels of symptom severity using the Rasch item threshold map. Results: The proposed methodology resulted in the development of CORE-6D, a 2-dimensional health state description system consisting of a unidimensionally-behaving 5-item emotional component and a physical symptom item. Inspection of the Rasch item threshold map of the emotional component helped identify a set of 11 plausible health states, which, combined with the physical symptom item levels, will be used for the valuation of the instrument, resulting in the development of a preference-based index. Conclusions: This is a useful new approach to develop preference-based measures where the domains of a measure are characterised by high correlation. The CORE-6D preference-based index will enable calculation of Quality Adjusted Life Years in people with common mental health problems

    Survey of ultrasound practice amongst podiatrists in the UK

    Get PDF
    Background: Ultrasound in podiatry practice encompasses musculoskeletal ultrasound imaging, vascular hand-held Doppler ultrasound and therapeutic ultrasound. Sonography practice is not regulated by the Health and Care Professions Council (HCPC), with no requirement to hold a formal qualification. The College of Podiatry does not currently define ultrasound training and competencies. This study aimed to determine the current use of ultrasound, training received and mentorship received and/or provided by podiatrists using ultrasound. Methods: A quantitative study utilising a cross-sectional, on-line, single-event survey was undertaken within the UK. Results: Completed surveys were received from 284 podiatrists; 173 (70%) use ultrasound as part of their general practice, 139 (49%) for musculoskeletal problems, 131 (46%) for vascular assessment and 39 (14%) to support their surgical practice. Almost a quarter (n=62) worked for more than one organisation; 202 (71%) were employed by the NHS and/or private sector (n=118, 41%). Nearly all (93%) respondents report using a hand-held vascular Doppler in their daily practice; 216 (82%) to support decisions regarding treatment options, 102 (39%) to provide diagnostic reports for other health professionals, and 34 (13%) to guide nerve blocks. Ultrasound imaging was used by 104 (37%) respondents primarily to aid clinical decision making (n=81) and guide interventions (steroid injections n=67; nerve blocks n=39). Ninety-three percent stated they use ultrasound imaging to treat their own patients, while others scan at the request of other podiatrists (n=28) or health professionals (n=18). Few use ultrasound imaging for research (n=7) or education (n=2). Only 32 (11%) respondents (n=20 private sector) use therapeutic ultrasound to treat patients presenting with musculoskeletal complaints, namely tendon pathologies. Few respondents (18%) had completed formal post-graduate CASE (Consortium for the Accreditation of Sonographic Education) accredited ultrasound courses. Forty (14%) respondents receive ultrasound mentorship; the majority from fellow podiatrists (n=17) or medical colleagues (n=15). Over half (n=127) who do not have ultrasound mentorship indicated they would like a mentor predominantly for ultrasound imaging. Fifty-five (19%) report they currently provide ultrasound mentorship for others. Conclusions: Understanding the scope of ultrasound practice, the training undertaken and the requirements for mentorship will underpin the development of competencies and recommendations defined by the College of Podiatry to support professional development and ensure safe practice.</p

    Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modelling

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To investigate the utility of three-dimensional guide-point modeling (GPM) to reduce the time required for CMR evaluation of global cardiac function in mice, by reducing the number of image slices required for accurate quantification of left-ventricular (LV) mass and volumes.</p> <p>Methods</p> <p>Five female C57Bl/6 mice 8 weeks post myocardial infarction induced by permanent occlusion of the left coronary artery, and six male control (un-operated) C57Bl/6 mice, were subject to CMR examination under isoflurane anaesthesia. Contiguous short axis (SAX) slices (1 mm thick 7-9 slices) were obtained together with two long axis (LAX) slices in two chamber and four chamber orientations. Using a mathematical model of the heart to interpolate information between the available slices, GPM LV mass and volumes were determined using full slice (all SAX and two LAX), six slice (four SAX and two LAX) and four slice (two SAX and two LAX) analysis protocols. All results were compared with standard manual volumetric analysis using all SAX slices.</p> <p>Results</p> <p>Infarct size was 39.1 ± 5.1% of LV myocardium. No significant differences were found in left ventricular mass and volumes between the standard and GPM full and six slice protocols in infarcted mice (113 ± 10, 116 ± 11, and 117 ± 11 mg respectively for mass), or between the standard and GPM full, six and four slice protocols in control mice, (105 ± 14, 106 ± 10, 104 ± 12, and 105 ± 7 mg respectively for mass). Significant differences were found in LV mass (135 ± 18 mg) and EF using the GPM four slice protocol in infarcted mice (p < 0.05).</p> <p>Conclusion</p> <p>GPM enables accurate analysis of LV function in mice with relatively large infarcts using a reduced six slice acquisition protocol, and in mice with normal/symmetrical left-ventricular topology using a four slice protocol.</p

    Viewpoint on Emv2, the onlhy endogenous ecotropic murine leukemia virus of C57BL/6 mice

    Get PDF
    Here I comment on the articles by Lee and colleagues (Retrovirology 2011, 8:82) and Lee and Cho (Retrovirology 2012, 9:23) dealing with an endogenous ecotropic mouse leukemia virus found in C57BL mice
    corecore